Durability of reinforced concrete and metal structures underground structure

Abstract

Durability of reinforced concrete and metal structures underground structure

Sysoev, A. K.

Incoming article date: 10.02.2019

The durability of reinforced concrete and metal structures of the underground structure depends on the design decision of the pavement over the construction and waterproofing of the structure as the most vulnerable part of the structure. The article considers the results of the survey of the state of reinforced concrete and metal structures, slabs and waterproofing coating of the musical theater in Rostov - on - don.Non-compliance with technological requirements in the manufacture of waterproofing coating in the underground garage led to corrosion damage to metal structures