  • Optimization of the location of fiber-optic communication lines on high-voltage power lines

    The article proposes a method for determining the optimal location of a self-supporting fiber-optic cable laid along the supports of high-voltage power transmission lines. The methodology is focused on the use of both a manual calculation method and with the use of electronic computing equipment.

    Keywords: fiber-optic communication line, electric field, induced voltage potential, electrothermal degradation, optimization of placement of self-supporting fiber-optic cable

  • Identification of object model parameters using a hybrid method

    In the work, a method was implemented that allowed estimating the parameters of a control object based on the objective function, the least squares method, and the solution to the system of nonlinear equations was the Levenberg-Marquardt method. The numerical and laboratory experiments carried out allow us to speak about the effectiveness of the proposed method.

    Keywords: identification, optimization, least squares method, Levenberg-Marquardt method, differential equation

  • The method of maintaining frequency in the power system by voltage regulation at electric power consumers

    The article raises the issue of maintaining the stability of the power system, including maintaining the balance of electric power. The occurrence of power imbalance can be determined by a criterion such as frequency. The authors have proposed a method of maintaining frequency including maintaining power balance in the power system by changing voltage on electric energy consumers, a hypothesis has been set and a corresponding laboratory study has been carried out, as a result of which dependence of frequency change on voltage of some electric power receivers has been obtained. A device an automatic unloading regulation of voltage has been developed and described, which will make it possible to supplement the existing emergency control equipment.

    Keywords: renewable energy sources, grid inverters, mode parameters, Clark conversions, Park conversions

  • Identification of parameters of electromagnetic equivalent circuits of submersible electric motor rotor packs. Definition reasonable circuits

    The article discusses the features of the use and applicability of identification of parameters of the equivalent circuit of an submersible electric motors. The possibilities of technical implementation with a given accuracy are evaluated for definition the parameters of submersible electric motors substitution circuits under various external influences, as well as when designing submersible electric motors as an integral part of the electro-technical complex of electrical submersible pump units.

    Keywords: submersible electric motor, electrical submersible pump unit, identification of parameters of the equivalent circuit of an asynchronous electric machine, mathematic simulation, crude oil production